GM 3100 Ex

The main task of the GM 3100 is the search for gas leaks in underground and exposed natural gas pipelines. However, it can also be used with the optional sensors to check e.g. biogas plants.

Dawnloads :
File
Display Illuminated LCD Display
Pump Diaphragm pump, flow rate adjustable and monitored
Sensitivity 1 ppm
Measurement ranges 1ppm – 2.2 vol.%
0 – 100  LEL
0 – 100 Vol.% CH4
0 – 100 Vol.% CO2(optional)
0 – 100 Vol.% O2 (optional)
0 – 500ppm CO (optional)
0 – 100ppm H2S (optional)
Sensors Semiconductor sensor
Infrared for CH4
Infrared for CO2 (optional)
Electrochemical sensors (optional)
Gas Types Flammable gases, natural gas, biogas, carbon dioxide, carbon monoxide, oxygen, hydrogen sulphide
Protection class IP 54
Ex protection EX d ib IIB T3 Gb, category II 2G
suitable for Ex zone 1
Energy Supply Battery 3x 1.5 V mono or battery 3x 1.2 V mono
Operating time 14 hours
Dimensions 215 x 100 x 60 mm
Weight 1.7 kg