• Unmatched sensor reliability for hydrogen sulfide H2S, carbon monoxide CO, or oxygen O2
• Adjustable alarm set points
• Real-time gas reading capability
• 0.1 ppm resolution for H2S sensor and display
• Two-way IR communication for event downloads, bump tests, detector configuration and firmware updates
• Programmable unique 6 digit detector identification
• Bump Test notification and confirmation when intervals are set
• Simple one button operation
• Calibration notification and confirmation when intervals are set
• Docking capability with Gas Clip Technologies SGC Dock
| Size • Weight | 3.4 H x 1.9 W x 1.1 D in. (85.5 x 48 x 29 mm.) • 2.7 oz. (76g) |
| Temperature | H₂S: -40°C to +50°C/-40°F to +122°F
CO: -40°C to +50°C/-40°F to +122°F O2: -35°C to +50°C/-31°F to +122°F |
| Humidity | 5% to 95% RH (non-condensing) |
| Battery Life | Two Years |
| Alarms | Visual, vibrating & audible (minimum 95 dB)
Detector life countdown (EOL), Low, High & Over limit (OL) |
| Display | High viewing angle Alphanumeric Liquid Crystal Display |
| Logs | 25 Events – newer events replace older events |
| Tests | Full function self-test upon activation and every 20 hours
Continuous automatic battery tests |
| Ratings | EMC Directive 2004/108/EC IP 67 |
| Certifications and Approvals | CSA: CSA16CA70075707
Intrinsically Safe/Sécurité lntrinsèque Class I, Division 1, Groups A, B, C and D; T4 EX ia IIC T4 Ga Class I, Zone 0, AEx ia IIC T4 Ga -40˚C ≤ Ta ≤ +50˚C (SGC H2S, SGC Plus H₂S, SGC CO) -35˚C ≤ Ta ≤ +50˚C (SGC O2) CAN/CSA-C22.2 No. 60079-0:19 CAN/CSA-C22.2 No. 60079-11:14 IECEx: IECEx CSA 16.0020 Ex ia IIC T4 Ga -40˚C ≤ Ta ≤ +50˚C (SGC H2S, SGC Plus H₂S, SGC CO) -35˚C ≤ Ta ≤ +50˚C (SGC O2) IEC 60079-0:2017 Edition: 7 IEC 60079-11:2011 Edition: 6 ATEX: SIRA 16ATEX2087; Ex ia IIC T4 Ga -40˚C ≤ Ta ≤ 50˚C (SGC H2S, SGC Plus H₂S, SGC CO) -35˚C ≤ Ta ≤ 50˚C (SGC O2) EN 60079-0:2018 EN 60079-11:2012 KCA: CSAE 21UKEX2476; Ex ia IIC T4 Ga -40˚C ≤ Ta ≤ 50˚C (SGC H2S, SGC Plus H₂S, SGC CO) -35˚C ≤ Ta ≤ 50˚C (SGC O2) EN 60079-0:2018 EN 60079-11:2012 |
| Warranty | Full Two years |
| Gases | H2SMeasuring range: 0-100 ppm
Low alarm limit: 10 ppm – High alarm limit: 15 ppm CO Measuring range: 0-300 ppm Low alarm limit: 35 ppm – High alarm limit: 200 ppm O2 Measuring range: 0-30% by vol. Low alarm limit: 19.5% – High alarm limit: 23.5% |
| Sensor Type | H2S, CO & O2 – Plug-in electrochemical cel |