Single Gas Clip

• Unmatched sensor reliability for hydrogen sulfide H2S, carbon monoxide CO, or oxygen O2
• Adjustable alarm set points
• Real-time gas reading capability
• 0.1 ppm resolution for H2S sensor and display
• Two-way IR communication for event downloads, bump tests, detector configuration and firmware updates
• Programmable unique 6 digit detector identification
• Bump Test notification and confirmation when intervals are set
• Simple one button operation
• Calibration notification and confirmation when intervals are set
• Docking capability with Gas Clip Technologies SGC Dock

Dawnloads :
File
Size • Weight 3.4 H x 1.9 W x 1.1 D in. (85.5 x 48 x 29 mm.) • 2.7 oz. (76g)
Temperature H₂S: -40°C to +50°C/-40°F to +122°F

CO: -40°C to +50°C/-40°F to +122°F

O2: -35°C to +50°C/-31°F to +122°F

Humidity 5% to 95% RH (non-condensing)
Battery Life Two Years
Alarms Visual, vibrating & audible (minimum 95 dB)

Detector life countdown (EOL), Low, High & Over limit (OL)

Display High viewing angle Alphanumeric Liquid Crystal Display
Logs 25 Events – newer events replace older events
Tests Full function self-test upon activation and every 20 hours

Continuous automatic battery tests

Ratings EMC Directive 2004/108/EC IP 67
Certifications and Approvals CSA: CSA16CA70075707

Intrinsically Safe/Sécurité lntrinsèque

Class I, Division 1, Groups A, B, C and D; T4 EX ia IIC T4 Ga

Class I, Zone 0, AEx ia IIC T4 Ga

-40˚C ≤ Ta ≤ +50˚C (SGC H2S, SGC Plus H₂S, SGC CO)

-35˚C ≤ Ta ≤ +50˚C (SGC O2)

CAN/CSA-C22.2 No. 60079-0:19

CAN/CSA-C22.2 No. 60079-11:14

IECEx: IECEx CSA 16.0020 Ex ia IIC T4 Ga

-40˚C ≤ Ta ≤ +50˚C (SGC H2S, SGC Plus H₂S, SGC CO)

-35˚C ≤ Ta ≤ +50˚C (SGC O2)

IEC 60079-0:2017 Edition: 7

IEC 60079-11:2011 Edition: 6

ATEX: SIRA 16ATEX2087; Ex ia IIC T4 Ga

-40˚C ≤ Ta ≤ 50˚C (SGC H2S, SGC Plus H₂S, SGC CO)

-35˚C ≤ Ta ≤ 50˚C (SGC O2)

EN 60079-0:2018

EN 60079-11:2012

KCA: CSAE 21UKEX2476; Ex ia IIC T4 Ga

-40˚C ≤ Ta ≤ 50˚C (SGC H2S, SGC Plus H₂S, SGC CO)

-35˚C ≤ Ta ≤ 50˚C (SGC O2)

EN 60079-0:2018

EN 60079-11:2012

Warranty Full Two years
Gases H2SMeasuring range: 0-100 ppm

Low alarm limit: 10 ppm – High alarm limit: 15 ppm

CO Measuring range: 0-300 ppm

Low alarm limit: 35 ppm – High alarm limit: 200 ppm

O2 Measuring range: 0-30% by vol.

Low alarm limit: 19.5% – High alarm limit: 23.5%

Sensor Type H2S, CO & O2 – Plug-in electrochemical cel
keyboard_arrow_up